  hbu60 series 60 w o pen fra me typ e m edi cal po we r s upp lies for he alth ca re app lica tion s the hbu60 series of compact, open frame constructed, ac/dc switching mode power supplies provide 60 w atts of continuous output power .they are suited for use in health care applications. all models meet fcc p ar t-18 class b and cispr -11 en55011 class b emission limits and are designed to comply with ul/c-ul(ul nd nd 60601-1:2 edition) ,tuv/t -mark(en 60601-1:2 edition) and new ce requirements. all units are 100% burned in and tested. electrical c har acteristics: f ea tur es: description: t y p . p a r a m e t e r t est conditions m i n . m a x . u n i t s a f e t y a p p r o v a l s i n p u t v o l t a g e r a n g e 240 100 v ac s y m . v in 0 0. 72 1. 62 1 v i n = 9 0 t o 2 6 4 v a c io =f ul l lo ad , vi n= 11 5v ac vi n= 23 0v ac w v a a a a a output power range e f f i c i e n c y li ne r eg ul at io n lo ad r eg ul at io n % % % 63 47 se e ra ti ng ch ar t 26 30 43 47 l o w l i n e i n r u s h c u r r e n t hz 5 i i l i r h e f f r e g - i reg - o i i h i r l fin po vo io 60 85 high lin e in rush cur rent i n p u t f r e q u e n c y output voltage range output current range input current (low line) input current (high line) io =f ul l lo ad , vi n= 23 0v ac io =f ul l lo ad , 25 c ,c oo l st ar t, vi n= 11 5v ac io =f ul l lo ad , 25 c ,c oo l st ar t, vi n= 23 0v ac io =f ul l lo ad se e ra ti ng ch ar t io =f ul l lo ad , vi n= 23 0v ac 1 0. 3 2 - 0 . 0 4 0 . 0 4 ti me of tr an si en t re sp on se h o l d - u p t i m e s a f e t y g r o u n d l e a k a g e c u r r e n t t e m p e r a t u r e c o e f f i c i e n t % % s ma m s 0. 3 0. 1 o c p o v p t t r t h o l d ts vp -p i l k tc 150 132 110 112 io =f ul l lo ad , vi n= 11 0v ac ov er c ur re nt p ro te ct io n ov er v ol ta ge p ro te ct io n i o = f u l l l o a d t o h a l f l o a d , v i n = 1 0 0 v a c s t a r t u p t i m e io =f ul l lo ad , vi n= 10 0v ac r i p p l e & n o i s e ( p e a k t o p e a k ) fu ll l oa d, v in =9 0v ac 1 % io =f ul l lo ad , vi n= 24 0v ac m s 12 16 4 %/ c al l ou tp ut 264 9 0 v ac o p e r a t e v o l t a g e r a n g e w id e o p e ra ti n g v o lt a g e 9 0 t o 2 6 4 v a c ,4 7 t o 6 3 h z s in g le o u tp u t in p u t c o n n e c to r m a te s w it h m o le x h o u s in g 0 9 -5 0 -3 0 3 1 /3 5 9 7 7 -0 3 0 0 a n d m o le x 2 4 7 8 / 3 5 9 2 2 s e ri e s c ri m p t e rm in a l. o u tp u t c o n n e c to r m a te s w it h m o le x h o u s in g 0 9 -5 0 -3 0 6 1 /3 5 9 7 7 -0 6 0 0 a n d m o le x 2 4 7 8 / 3 5 9 2 2 s e ri e s c ri m p t e rm in a l. in p u t s u rg e c u rr e n t, o v e r v o lt a g e a n d o v e r lo a d p ro te c ti o n s iz e : 2 "x 4  x 1  c la s s i 2 y e a r w a rr a n ty saf ety a ppr o vals : c b c b en vir onmental : toper o p e r a t i n g t e m p e r a t u r e tstg s t o r a g e t e m p e r a t u r e 0 70 85 40 -40 s y m . p a r a m e t e r m i n . t y p . m a x . u n i t t e s t condi tions c c hr h o stora ge hu midit y 75 % % o p e r a t i n g h u m i d i t y pd 0 9 5 0 derat e lin early from 100% load at 4 0 c t o 50% load at 7 0 c hrs mtbf o p e r a t i n g t e m p e r a t u r e a t 2 5 c , c a l c u l a t e d p e r m i l - h d b k - 2 1 7 f 0.1m e n 6 0 6 0 1 - 1 i e c 6 0 6 0 1 - 1
hbu60 series output v olta ge and cur r ent r a ting c har t (sing le output) : mec hanical specifica tions : n o t e : 1 . d i m e n s i o n s a r e s h o w n i n i n c h e s o r m m . 2 . w e i g h t : 1 4 0 g s a p p r o x . 3 . i n p u t c o n n e c t o r m a t e s w i t h m o l e x h o u s i n g 0 9 - 5 0 - 3 0 3 1 / 3 5 9 7 7 - 0 3 0 0 a n d m o l e x 2 4 7 8 / 3 5 9 2 2 s e r i e s c r i m p t e r m i n a l . 4 . o u t p u t c o n n e c t o r m a t e s w i t h m o l e x h o u s i n g 0 9 - 5 0 - 3 0 6 1 / 3 5 9 7 7 - 0 6 0 0 a n d m o l e x 2 4 7 8 / 3 5 9 2 2 s e r i e s c r i m p t e r m i n a l . saf ety specifica tions: p a r a m e t e r t e s t conditions m i n . t y p . m a x . u n i t d i e l e c t r i c w i t h s t a n d i n g v o l t a g e f o r p r i m a r y t o s e c o n d a r y primary to secondary 5656 vdc s y m . vps d i e l e c t r i c w i t h s t a n d i n g v o l t a g e f o r p r i m a r y t o g r o u n d primary to ground 2828 vdc vp g i s o l a t i o n r e s i s t a n c e test voltage=500vdc 50 ris vin=220vac b class c i s p r fcc e m i r e q u i r e m e n t s f o r c i s p r - 1 1 vin=110vac b class e m i r e q u i r e m e n t s f o r f c c p a r t - 1 8 m p i n c h a r t m o d e l p i n h b u 6 0 - 1 x x 1 2 3 4 5 6 o u t r t n r t n r t n o u t o u t 60 w o pen fra me typ e m edi cal po we r s upp lies for he alth ca re app lica tion s m o d e l nu m b e r o u t p u t v o lt a g e o u t p u t c u r r e n t t o t a l r e g u la t io n m a x im u m o u t p u t p o w e r h bu 60 - 10 5 0 1 2 ~ 13 vdc 5 .00 ~ 4 . 61 a 5 % 6 0 w h bu 60 - 10 6 0 1 3 ~ 16 vdc 4 . 61 ~ 3 . 75 a 5 % 6 0 w h bu 60 - 10 7 16 ~ 2 1 vdc 3 . 75 ~ 2 . 8 5 a 5 % 6 0 w h bu 60 - 10 8 2 1 ~ 27 vdc 2. 85 ~ 2. 22 a 3 % 6 0 w h bu 60 - 10 9 27 ~ 33 vdc 2. 22 ~ 1 . 8 1 a 3 % 6 0 w h bu 60 - 1 10 3 3 ~ 40 vdc 1 . 8 1 ~ 1. 50 a 3 % 6 0 w


▲Up To Search▲   

 
Price & Availability of HBU60

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X